8 OUTPUT MODULE
(7) Comment
(a) This device is used to create a comment such as purpose of cam shaft.
Made comment can be displayed at monitoring using a peripheral device.
(b) Comments up to 32 characters long can be created.
(8) Lower stroke limit value storage device (2 words)
(a) This device is used to store the cam lower stroke limit value.
The current lower stroke limit value is stored.
(b) The following devices can be set as the lower stroke limit value storage
device.
Name
Data register
Link register
(Note-1) : Set an even number at the first device.
(Note-2) : D800 to D1559 are dedicated devices of virtual servomotor axis,
synchronous encoder axis and output module "Cam" in the virtual mode.
Unused areas of virtual servomotor axis and cam axis can be used as a
user device.
(c) The lower stroke limit value is range of -2147483648 (-2
31
(2
-1).
1) The lower stroke limit value is determined as follows for each unit setting:
[mm]: Lower stroke limit value 10
[inch]: Lower stroke limit value 10
[PLS : Lower stroke limit value 1 [PLS]
(9) Current value within 1 virtual axis revolution storage device
(Main shaft side) (2 words)
This parameter is set when the address mode clutch is set at the cam main shaft
side.
Drive module
Current value within 1 virtual
axis revolution
Address mode clutch
Cam
(a) The current value within 1 virtual axis revolution of cam main shaft side is
stored in the preset device.
(Note-1)
Setting range
D800 to D3069
D3080 to D8191
W0 to W1FFF
-1
[µm]
-5
Current value within 1 virtual axis revolution
= (Drive module travel value
(Nc-1)
PLS
8 - 32
(Note-2)
31
) to 2147483647
[inch]
(% : Remainder operator)
0
0
0
0
gear) %Nc