Download Print this page

Starting/Stopping The Pump With The Lcd Controller - EBARA ESA500W Instruction Manual

Multi-stage dry vacuum pump, 200v/400v, 50hz, 200-220v/400-480v, 60hz

Advertisement

[NOTE] When parameter setting of the dip switches, other than dip switch-A
No.3 (BUZZER) and B-8 (LCD initialize), is performed, the LCD
controller counts down 10 seconds, the same as at the power on state,
right after the completion of the parameter setting.
[NOTE] If any warning or alarm occurs during the parameter setting, the setting
session will be stopped automatically and the display will be
changed to the warning & alarm display screen.

6.6 Starting/stopping the pump with the LCD controller

Maximum two LCD controllers can be connected. Note only one of them
can start and stop the pump (the other shows the pump operational statuses).
The controller of which LED "LOCAL" is lit on has precedence over the other
to control the start and stop operation.
If only one controller is connected, the controller starts and stops the pump.
START/STOP
When you use two controllers, disconnect the one which you will not use for
the operation from the pump once. Then, attach it again.
PM10U
One controller
Two controller connected
connected
The one with its LED
Allowed
"LOCAL" lit on is allowed.
P.41
EBARA
CORPORATION

Hide quick links:

Advertisement