7.2.3 COMMUNICATION Start/Stop

a) START
Enter the external "MP" start signal input through the communication connector.
The MP starts.
In the automatic BP operating mode, the BP can be started/stopped automatically.
When the BP is operated under external start command input, apply the external
BP start command to the communication connector. The power is indicated on
the display during pump operation. For other status display indications, refer
to Table 6.1.
[NOTE] The pump will not start when an ALARM/WARNING has been generated.
When a START signal is entered, "STARTFAIL" will appear on the display.
BP can be started/stopped by the external signal when the DIPswitch set
accordingly.
b) STOP
Interrupt the external MP start command and the pump will stop.
*Please refer to the COMMUNICATION SPCIFICATIONS in detail.
PM10U
P.47