Download Print this page

Dip Switch - EBARA ESA500W Instruction Manual

Multi-stage dry vacuum pump, 200v/400v, 50hz, 200-220v/400-480v, 60hz

Advertisement

P.36

6.4 Dip Switch

Set the dipswitches to select the operating modes as shown in Table 6.4, 6.5 and 6.6.
No.
1
Data Length
2
Monitor Cooling water and N2
3
Buzzer
4
Operation switched to Remote
5
External start/stop signal *
6
-----
7
-----
8
BP operation in Remote
* Optional
No.
1
2
3
4
Pump N2 valve control*
5
6
Remote Interface (IF)
7
Phase error monitoring
8
LCD screen initialize
* Optional
No.
1
Outputs the pump N2 warning.
2
3
Outputs backpress. warning. *
4
5
6
7
8
* Optional
DIP SW-A. No.1
PM10U
Table 6.4 Dip Switch-A Settings
Mode
According to signal
Alternate (Level)
Automatic operation
Table 6.5 Dip Switch-B Settings
Mode
-----
-----
-----
-----
Exclusive special IF
Carry out initialize
Table 6.6 Dip Switch-C Settings
Mode
Normal Open
-----
Normal Open
-----
-----
-----
-----
-----
In case of observing pump running status with RS232C
communication port, Data Length can be selected out of
7bits and 8bits.
Off
7bits
Always
Only during operation
Not used
Automatically stop
Momentary (Pulse) *
-----
-----
External signal input
Off
-----
-----
-----
No
-----
No use / standard IF
Standard
During starting only
Do not initialize
Off
Normal Close
-----
Normal Close
-----
-----
-----
-----
-----
On
Factory
setting
8bits
ON
OFF
Use
ON
OFF
OFF
-----
-----
-----
-----
OFF
On
Factory
setting
-----
-----
-----
-----
-----
-----
Yes
OFF
-----
-----
ON
OFF
OFF
On
Default
OFF
-----
-----
OFF
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
EBARA
CORPORATION

Hide quick links:

Advertisement

loading