Download Print this page

EBARA ESA500W Instruction Manual page 52

Multi-stage dry vacuum pump, 200v/400v, 50hz, 200-220v/400-480v, 60hz

Advertisement

Characters displayed on LCD screen during dip switch setting
No.
1
communication data
2
3
4
Remote/Local setting
5
Type of Input signal *
6
7
8
No.
1
2
3
4
5
6
7
Phase error monitoring
8
LCD screen initialize
No.
1
2
3
4
5
6
7
8
* Optional
PM10U
MODE
Length of
Monitor condition of
cooling water /
Nitrogen
Buzzer
-----
-----
BP operation under
REMOTE mode
MODE
-----
-----
-----
-----
-----
Remote Interface
MODE
PumpN2 Warning
output
-----
Back Pressure
Warning output
-----
-----
-----
-----
-----
Dip switch A
OFF
A1:DATA LENGTH
7BIT
A2:WATER&N2
WATCHING ALWAYS
A3:BUZZER
INACTIVE
A4:REM. ACTION
CONCORD
A5:REM. SIGNAL
ALTERNATE
A6:NO ASSIGNED
A7:NO ASSIGNED
A8:BP REM. MODE
AUTO
Dip switch B
OFF
B1:NO ASSIGNED
B2:NO ASSIGNED
B3:NO ASSIGNED
B4:NO ASSIGNED
B5:NO ASSIGNED
B6:REMOTEI/O
OPTION
B7:PHASE ERROR
STANDARD
B8:LCD DISPLAY
INITIALIZING
Dip switch C
OFF
C1:PUMP N2 WARN
OUTPUT N.OPEN
C2:NO ASSIGNED
C3:BACK PRES.
OUTPUT N.OPEN
C4:NO ASSIGNED
C5:NO ASSIGNED
C6:NO ASSIGNED
C7:NO ASSIGNED
C8:NO ASSIGNED
ON
A1:DATA LENGTH
8BIT
A2:WATER&N2
ONLY RUNNING
A3:BUZZER
ACTIVE
A4:REM. ACTION
STOP
A5:REM. SIGNAL
MOMENTARY*
A6:NO ASSIGNED
A7:NO ASSIGNED
A8:BP REM. MODE
EXTERNAL INPUT
ON
B1:NO ASSIGNED
B2:NO ASSIGNED
B3:NO ASSIGNED
B4:NO ASSIGNED
B5:NO ASSIGNED
B6:REMOTE I/O
STANDARD
B7:PHASE ERROR
COUNTDOWN ONLY
B8:LCD DISPLAY
UN-INITIALIZING
ON
C1:PUMP N2 WARN
OUTPUT N.CLOSE
C2:NO ASSIGNED
C3:BACK PRES.
OUTPUT N.CLOSE
C4:NO ASSIGNED
C5:NO ASSIGNED
C6:NO ASSIGNED
C7:NO ASSIGNED
C8:NO ASSIGNED
EBARA
CORPORATION
P.39

Hide quick links:

Advertisement

loading