[NOTE]
When parameter setting of the dip switches, other than dip switch-A
No.3 (BUZZER), is performed, the LCD controller counts down 10
seconds, the same as at the power on state, right after the
completion of the parameter setting.
[NOTE]
If any warning or alarm occurs during the parameter setting, the
setting session will be stopped automatically and the display will be
changed to the warning & alarm display screen.

6.6 Starting/stopping the pump with the LCD controller

Maximum two LCD controllers can be connected. Note only one of them can
start and stop the pump (the other shows the pump operational statuses).
The controller of which LED "LOCAL" is lit on has precedence over the other to
control the start and stop operation.
If only one controller is connected, the controller starts and stops the pump.
START/STOP
When you use two controllers, disconnect the one which you will not use for the
operation from the pump once. Then, attach it again.
One controller
connected
The one with its LED
Allowed
"LOCAL"
allowed.
(49)
Two controller
connected
lit
on
is