15. Remove four screws (A to D) and then
remove the LSU.
16. Check or replace the LSU and refit all
the removed parts.
*: To re-mount the LSU, secure the
screws in the order of A – B – C- D.
17. When replacing the new LSU, proceed as follows:
1)Perform maintenance mode U930 (checking/ clearing the charger roller count) and checking the coun-
ter value (see page 1-3-196).
2)Perform maintenance mode U119 (Setting the drum) (see page 1-3-76).
3)Perform maintenance mode U930 (checking/clearing the charger roller count) and input the counter
value (see page 1-3-196).
4)Perform maintenance mode U464 (Calibration) (see page 1-3-175).
5)Perform maintenance mode U412 (Adjusting the uneven density) (see page 1-3-161).
6)Perform maintenance mode U464 (Calibration) (see page 1-3-175).
7)Perform maintenance mode U410 (Adjusting the halftone automatically) (see page 1-3-151).
LSU
Screw D
Screw A
Figure 1-5-88
1-5-52
Screw B
Screw C
2N8/2N7