Connector
Pin
1
GND
YC1
Connected to
2
REG_F_LED
engine PWB
3
REG_SENS_F_P
4
REG_SENS_F_S
5
GND
6
REG_R_LED
7
REG_SENS_RP(B
K)
8
REG_SENS_RS(B
K)
9
CLN_SOL_REM
10
CLN_SOL_RET
11
GND
12
BELT_JAM_SENS
13
DU_SENS
14
PRESS_RLS_SEN
S
15
PRESS_RLS_MOT
_REM2
16
PRESS_RLS_MOT
_REM1
17
DU_FAN
18
DU_OPEN
19
GND
20
DU2_REM(CL_LO
W)
21
DU2_CLK
22
DU2_PD
23
INTER_LOCK
24
GND
25
GND
26
GND
27
GND
28
GND
29
MPF_LIFT1
30
MPF_LIFT2
31
MPF_CL
Signal
I/O
-
-
I
Analog
O
Analog
O
Analog
-
-
I
Analog
O
Analog
O
Analog
I
0/24 V DC
I
0/24 V DC
-
-
-
-
O
0/3.3 V DC
O
0/3.3 V DC
I
0/24 V DC
I
0/24 V DC
-
-
O
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC (pulse) DUM2 clock signal
I
0/3.3 V DC
O
0/24 V DC
-
-
-
-
-
-
-
-
-
-
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
Voltage
Ground
IDS1 control signal
IDS1 detection signal
IDS1 detection signal
Ground
IDS2 control signal
IDS2 detection signal
IDS2 detection signal
CLSOL: On/Off (ACT)
CLSOL: On/Off (RET)
Ground
Not used
DUS2: On/Off
TRRS: On/Off
TRRM: On/Off
TRRM: On/Off
Not used
DUCSW: On/Off
Ground
DUM2/DUCL2: On/Off
DUM2 control signal
PCUSW: On/Off
Ground
Ground
Ground
Ground
Ground
MPLM: On/Off
MPLM: On/Off
MPPFCL: On/Off
2-3-54
2N8/2N7
Description