Connector
Pin
YC1
1
AC_LIVE
2
AC_NEUTRAL
Connected to
Inlet2
YC4
1
SGAND
Connected to
2
Vcc
engine PWB
3
IH_REM
4
ROTATION
5
RXD
6
TXD
YC5
1
LIVE_OUT
Connected to
2
fuser heater
3
NEUTRAL_OUT
and fuser-
4
thermostat 2
5
NEUTRAL_OUT
YC6
1
+15V1
Connected to
2
+15V2
fuser thermo-
stat 1
YC8
1
FSR_RELAY_24V
Connected to
2
+24V1
feed PWB 1
3
FSR_RELAY
4
GND
5
GND
6
ZEROC
7
+24V2
8
PRESS_REM
YC9
1
VS
Connected to
Fuser IH
YC10
1
COIL_COM
Connected to
Fuser IH
Signal
I/O
I
120 V AC
I
120 V AC
-
-
I
3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC (pulse) FIH control signal
I
0/3.3 V DC (pulse) Serial communication data signal
O
0/3.3 V DC (pulse) Serial communication data signal
O
120 V AC
-
-
O
120 V AC
-
-
O
15 V DC
I
15 V DC
I
0/3.3 V DC
I
24 V DC
I
0/3.3 V DC
-
-
-
-
-
-
I
24 V DC
I
0/3.3 V DC
O
70 V to 185 V AC
O
70 V to 185 V AC
Voltage
120V AC power input
120V AC power input
Ground
3.3 V DC power from EPWB
FIH: On/Off
AC power output to FTS2
Not used
AC power output to FH
Not used
15V DC power to FTS1
15V DC power from FTS1
Fuser relay signal
24 V DC power from feed PWB 1
Fuser relay signal
Ground
Ground
Not used
24 V DC power from feed PWB 1
Fuser heater remote signal
Resonant circuit output to the IH coil
Resonant circuit output to the IH coil
2-3-33