Setting Transfer High-Voltage Timing; Initial Setting For The Developer - Kyocera TASKalfa 6501i Service Manual

Hide thumbs Also See for TASKalfa 6501i:
Table of Contents

Advertisement

Item No.
U128

Setting transfer high-voltage timing

Description
Adjusts the ON/OFF timing of transfer high-voltage output.
Purpose
Basically, the setting need not be changed. If any problem such as faulty images or dirt on the
back surface occurs, change the setting.
Method
1. Press the start key.
2. Select the item to set.
3. Change the value using the +/- keys or numeric keys.
Display
On Timing
1st
Off Timing
* : Increasing the value will deteriorate paper separation as it delays transfer-off timing.
* : Decreasing the value will improve paper separation as it advances transfer-off timing (wid-
ening the transfer margins at the trailing edge of paper at ejection).
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U130

Initial setting for the developer

Description
The toner sensor control bias is adjusted so that the sensor output is set as the target value with
the initial developer.
Purpose
Automatically executed when the developer unit loaded with the initial developer is replaced.
Method
1. Press the start key.
2. Select [Execute].
3. Press the start key.
Toner installation is started and the control value of the toner sensor is displayed.
K
Execute
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Transfer ON timing adjust-
ment value (first side)
Transfer OFF timing adjust-
ment value
Display
Toner sensor control voltage
Execute
Description
Setting
range
-200 to 200
-13
-200 to 200
-20
Description
1-3-78
Initial setting
65ppm
80ppm
-10
-21
2N8/2N7