Emergency-UPDATE

If Safe Update is processed to the end, the firmware update is complete. In
case the message below is indicated, update the firmware after recovery with
the steps below.
Note that this is unoperable when the device is operating normally.
Preparation
The USB flash device must be formatted in FAT or FAT32 in advance.
Extract the main firmware to download from the file.
Rename the file which was extracted from the archive. [DL_CTRL.2N7] to [KM_EMRG.2N7]
Copy the all extracted files to the root of the USB flash device.
Procedure
1. Turn the main power switch off.
2. Insert the USB flash device in which the
firmware was copied into the USB flash
device slot at the left of the machine.
3. Turn the main power switch on.
4. Rewriting of the PWB software will start
for restoration.
(The LCD, memory LED, and attention
LED on the operation panel will be
showing the progress.)
Caution:
Never turn off the power switch or
remove the USB flash device during
upgrading.
5. The operation panel LCD will show
"Completed" when rewriting has been
finished.
* : In case rewriting has been failed, "Error
XXXX" (XXXX means an error code)
will be shown.
6. Turn the main power switch off.
7. Wait for several seconds and then
remove the USB flash device from the
machine.
8. Insert the USB flash device in which an
upgrade pack of the latest firmware or
the Main/MMI/Browser and LAN-
GUAGE BR (excluding Dictionary) were
copied, into the slot on the machine and
turn power on. (see page P.1-6-1).
T 1
O P
USB flash device
Figure 1-6-2
1-6-2
2N8/2N7-5
FW-Update
Error FFFF