Kyocera TASKalfa 6501i Service Manual page 730

Hide thumbs Also See for TASKalfa 6501i:
Table of Contents

Advertisement

12. Remove the stop ring from the DP origi-
nal feed belt shaft B.
13. Pull out the DP original feed belt shaft B
from the DP original feed belt unit.
14. Remove the DP feed collar B and DP
original feed belt from the DP original
feed belt shaft B.
15. Remove the stop ring from the DP for-
warding pulley shaft.
16. Pull out the DP forwarding pulley shaft
from the DP original feed unit and then
remove the DP forwarding pulley.
17. Check or replace the DP original feed
belt and DP forwarding pulley and refit
all the removed parts.
DP original feed
collar B
Stop ring
DP original feed belt
Figure 1-5-193
DP original
feed unit
DP forwarding
pulley
Bush
Stop ring
Figure 1-5-194
1-5-118
2N8/2N7
DP original feed
belt shaft B
DP original feed
belt unit
Pulley
DP forwarding
pulley shaft

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 8001i

Table of Contents