7. The CCD unit Height Adjustment 2
In case of white vertical lines appear like the illustration "b" on page 1.
1. Set the spacer (large) (B) into the inside
screw holes at the lens side.
2. Check the image.
In case of no problem on the image, go
to "9. Image Adjustment".
In case of the problem on the image, go
to "8. Re-adjustment 2".
8. Re-adjustment 2
1. In case the white vertical lines still
appear.
c: Insert the additional spacer (small)
(C)
In case the whitish or background
image appears.
d: Remove the spacer (large) (B) and
insert the spacer (small) (C).
2. Check the image and go to "9. Image
Adjustment".
9. Image Adjustment
Execute the U411 Auto Adjustment (see page 1-3-152).
Set a new auto adjustment chart (part no. 7505000005) on the contact glass.
Execute the U411- Target – Auto – Table (chart1) - ALL.
10. Refit all the removed parts.
Figure 1-5-80
c
d
Figure 1-5-81
1-5-48