Problem
(51)
DP conveying
motor does not
operate.
(52)
DP eject motor
does not operate.
(53)
DP fan motor 1
does not operate.
(54)
DP fan motor 2
does not operate.
(55)
An original jams
when the main
power switch is
turned on.
Causes
1. Defective connector
cable or poor con-
tact in the connector.
2. Defective drive trans-
mission system.
3. Defective motor.
4. Defective PWB.
1. Defective connector
cable or poor con-
tact in the connector.
2. Defective connector
cable or poor con-
tact in the connector.
3. Defective motor.
4. Defective PWB.
1. Defective connector
cable or poor con-
tact in the connector.
2. Defective fan motor.
3. Defective PWB.
1. Defective connector
cable or poor con-
tact in the connector.
2. Defective fan motor.
3. Defective PWB.
1. A piece of paper torn
from an original is
caught around the
DP feed sensor, DP
CIS sensor, DP
timing sensor, DP
eject sensor.
2. Defective sensor.
Check procedures/corrective measures
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP conveying motor and DP main PWB (YC14)
Check if the rollers and gears rotate smoothly. If not,
grease the bushes and gears. Check for broken gears and
replace if any.
Replace the DP conveying motor.
Replace the DP main PWB and check for correct operation.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP eject motor and DP main PWB (YC14)
Check if the rollers and gears rotate smoothly. If not,
grease the bushes and gears. Check for broken gears and
replace if any.
Replace the DP eject motor.
Replace the DP main PWB and check for correct operation.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP fan motor 1 and DP main PWB (YC7)
Replace the DP fan motor 1.
Replace the DP main PWB and check for correct operation.
Reinsert the connector. Also check for continuity within the
connector cable. If none, replace the cable.
DP fan motor 2 and DP main PWB (YC8)
Replace the DP fan motor 2.
Replace the DP main PWB and check for correct operation.
Check visually and remove it, if any.
Replace the DP feed sensor, DP CIS sensor, DP timing
sensor or DP eject sensor.