Serial command mode trigger only at boot up
Command code: CB
Command parameters: 0 if serial command mode can be triggered at any time, or 1 if it can only be triggered
at boot up.
Note that this configuration is valid only if serial command mode trigger method is set to `Activated by
characters'.
Reply parameters: N/A
?SCB1
!SCB0
Gratuitous ARP
Command code: VA
Command parameters: 1 and send period if gratuitous ARP is enable; otherwise, 0.
Reply parameters: N/A
?SVA1;300
!SVA0
Command Code for Retrieving Running
Configuration
Device Name
Command code: BN
Command parameters: N/A
Reply parameters: MiiNePort's name.
?RBN
!RBN0MiiNePort_9527
Console Password
Command code: BP
Command parameters: N/A
Reply parameters: MiiNePort's console password.
?RBP
!RBP01234
Web console
Command code: BH
Command parameters: N/A
Reply parameters: 1 and web console TCP port separated by a semicolon (;) if web console is enabled, or a 0
if it is disabled.
?RBH
!RBH01;80
Introduction to SCM (Serial Command Mode) Command Set
System sets serial command mode can only be triggered by characters at
boot up.
MiiNePort reports command executed successfully.
System sets gratuitous ARP as 'Enable' and send period as '300' sec for this
MiiNePort.
MiiNePort reports command executed successfully.
System requests configured device name for this MiiNePort.
MiiNePort reports device name as 'MiiNePort_9527'.
System requests console password for this MiiNePort.
MiiNePort reports console password as '1234'.
System requests http console setting for this MiiNePort.
MiiNePort reports http console as 'Enable' and http port as '80'.