Moxa Technologies MiiNePort E2-H User Manual page 131

Miineport e2/e3
Hide thumbs Also See for MiiNePort E2-H:
Table of Contents

Advertisement

MiiNePort E2/E3
UDP local listen port
Command code: UP
Command parameters: Two numbers separated by a semicolon (;) denote port index and MCSC channel index.
For an MCSC-disabled port, the channel index is 0.
Reply parameters: local listen port.
?RUP1;0
!RUP04001
E-modem TCP alive check time
Command code: EA
Command parameters: Two numbers separated by a semicolon (;) denotes port index and MCSC channel index.
For MCSC-disabled port, channel index shall be 0.
Reply parameters: 1 (Enable) or 0 (Disable)
?REA1;0↲
!REA05↲
E-modem local listen port
Command code: EP
Command parameters: Two numbers separated by a semicolon (;) denotes port index and MCSC channel index.
For MCSC-disabled port, channel index shall be 0.
Reply parameters: local listen port
?REP1;0↲
!REP01234↲
DIO initial mode
Command code: PM
Command parameters: DIO port index. For MiiNePort E2, the index is as following:
Index
DIO port
0
DIO0
1
DIO1
2
DIO2
3
DIO3
Reply parameters: 1 (output) or 0 (input) , note that for MiiNePort E2, this configuration is available if specific
PIN function is set to DIO.
?RPM1↲
!RPM01↲
Introduction to SCM (Serial Command Mode) Command Set
System requests UDP local listen port for port 1.
MiiNePort reports UDP local listen port as '4001'.
System requests for alive check time for port1.
MiiNePort reports alive check time is '5'.
System requests for E-modem local listen port for port 1.
MiiNePort reports E-modem local listen port is '1234'.
MiiNePort E2 PIN number
JP3 - PIN1
JP3 - PIN4
JP3 – PIN2
JP3 - PIN3
System requests DIO1's initial mode for this MiiNePort.
MiiNePort reports DIO1's initial mode is 'output'.
A-39

Advertisement

Table of Contents
loading

Table of Contents