MiiNePort E2/E3
Baudrate
Command code: SB
Command parameters: Port index and baudrate separated by a semicolon (;).
Reply parameters: N/A
?SSB1;115200
!SSB0
Data bits
Command code: SD
Command parameters: Port index and data bits separated by a semicolon (;).
Reply parameters: N/A
?SSD1;8
!SSD0
Stop bits
Command code: SS
Command parameters: Port index and stop bits separated by a semicolon (;). MiiNePort's Stop bits index as
shown in the following table:
0
Stop bits is 1
1
Stop bits is 1.5
2
Stop bits is 2
Reply parameters: N/A
?SSS1;0
!SSS0
Parity
Command code: SP
Command parameters: Port index and parity separated by a semicolon (;). MiiNePort's Parity index as shown
in the following table:
0
None
1
Odd
2
Even
3
Mark
4
Space
Reply parameters: N/A
?SSP1;0
!SSP0
Introduction to SCM (Serial Command Mode) Command Set
System sets port 1's baudrate as '115200'.
MiiNePort reports command executed successfully.
System sets port 1's data bits as '8'.
MiiNePort reports command executed successfully.
System sets port 1's stop bits as '1'.
MiiNePort reports command executed successfully.
System sets port 1's parity bit as 'None'.
MiiNePort reports command executed successfully.
A-20