MiiNePort E2/E3
Command Code for Setting the Configuration
Device Name
Command code: BN
Command parameters: The new device name for the MiiNePort.
Reply parameters: N/A
?SBNMiiNePort@Office
!SBN0
Password
Command code: BP
Command parameters: MiiNePort's console password
Reply parameters: N/A
?SBP1234
!SBP0
Web console
Command code: BH
Command parameters: 1 and web console TCP port to enable web console, or 0 to disable it.
Reply parameters: N/A
?SBH1;80
!SBH0
Telnet console
Command code: BT
Command parameters: 1 and telnet console TCP port to enable telnet console, or 0 to disable it.
Reply parameters: N/A
?SBT1;23
!SBT0
Auto configuration
Command code: BA
Command parameters: 1 if Auto configuration is enabled, 0 otherwise.
Reply parameters: N/A
?SBA1
!SBA0
Introduction to SCM (Serial Command Mode) Command Set
System sets the device name as 'MiiNePort@Office'.
MiiNePort reports command executed successfully.
System sets console password as '1234' for this MiiNePort.
MiiNePort reports command executed successfully.
System sets http console as 'Enable' and http port as '80' for this MiiNePort.
MiiNePort reports command executed successfully.
System sets telnet console as 'Enable' and telnet port as '23' for this
MiiNePort.
MiiNePort reports command executed successfully.
System sets auto configuration as 'Enable' for this MiiNePort.
MiiNePort reports command executed successfully.
A-16