Command Code For Getting The Configuration - Moxa Technologies MiiNePort E2-H User Manual

Miineport e2/e3
Hide thumbs Also See for MiiNePort E2-H:
Table of Contents

Advertisement

MiiNePort E2/E3

Command Code for Getting the Configuration

Device Name
Command code: BN
Command parameters: N/A
Reply parameters: MiiNePort's name.
?GBN
!GBN0MiiNePort_E2_9527 
Console Password
Command code: BP
Command parameters: N/A
Reply parameters: MiiNePort's console password.
?GBP
!GBP01234
Web console
Command code: BH
Command parameters: N/A
Reply parameters: 1 and web console TCP port separated by a semicolon (;) if web console is enabled, or a 0
if it is disabled.
?GBH
!GBH01;80
Telnet console
Command code: BT
Command parameters: N/A
Reply parameters: 1 and telnet console TCP port separated by a semicolon (;) if telnet console is enabled, or
a 0 if it is disabled.
?GBT
!GBT01;23
Auto configuration
Command code: BA
Command parameters: N/A
Reply parameters: 1 if Auto configuration is enabled, 0 otherwise.
?GBA
!GBA01
Introduction to SCM (Serial Command Mode) Command Set
System requests configured device name for this MiiNePort.
MiiNePort reports device name as 'MiiNePort_E2_9527'
System requests console password for this MiiNePort.
MiiNePort reports console password as '1234'.
System requests http console setting for this MiiNePort.
MiiNePort reports http console as 'Enable' and http port as '80'.
System requests telnet console setting for this MiiNePort.
MiiNePort reports telnet console as 'Enable' and telnet port as '23'.
System requests Auto configuration setting for this MiiNePort.
MiiNePort reports Auto configuration as 'Enable'.
A-3

Advertisement

Table of Contents
loading

Table of Contents