MiiNePort E2/E3
Parity
Command code: SP
Command parameters: Port index
Reply parameters: MiiNePort's Parity index as follows.
0
None
1
Odd
2
Even
3
Mark
4
Space
?RSP1
!RSP00
Flow control
Command code: SL
Command parameters: Port index.
Reply parameters: MiiNePort's Flow control index as follows.
0
None
1
RTS/CTS
2
XON/XOFF
3
DTR/DSR
?RSL1
!RSL01
FIFO
Command code: SF
Command parameters: Port index.
Reply parameters: 1 (Enable) or 0 (Disable) MiiNePort's FIFO.
?RSF1
!RSF01
Interface
Command code: SI
Command parameters: Port index.
Reply parameters: 0 (RS232) or 1 (RS485-2wire) MiiNePort's Interface.
?RSI1;0↲
!RSI0↲
Introduction to SCM (Serial Command Mode) Command Set
System requests port 1's Parity for this MiiNePort.
MiiNePort reports Parity as 'None'.
System requests port 1's Flow control for this MiiNePort.
MiiNePort reports Flow control as 'RTS/CTS'.
System requests port 1's FIFO for this MiiNePort.
MiiNePort reports FIFO as 'Enable'.
System sets port1's interface as 'RS232'.
MiiNePort reports command executed successfully.
A-33