Moxa Technologies MiiNePort E2-H User Manual page 109

Miineport e2/e3
Hide thumbs Also See for MiiNePort E2-H:
Table of Contents

Advertisement

MiiNePort E2/E3
NECI (utility accessibility)
Command code: BU
Command parameters: 1 if NECI is enabled, 0 otherwise.
Reply parameters: N/A
?SBU1
!SBU0
IP configuration
Command code: NC
Command parameters: MiiNePort's IP configuration index as shown in the following table
Reply parameters: N/A
0
Static
1
DHCP
2
DHCP/BOOTP
3
BOOTP
4
AutoIP
?SNC0
!SNC0
IP address
Command code: NI
Command parameters: MiiNePort's IP address.
Reply parameters: N/A
?SNI192.168.1.2
!SNI0
Netmask
Command code: NM
Command parameters: MiiNePort's Netmask address.
Reply parameters: N/A
?SNM255.255.255.0
!SNM0
Gateway
Command code: NG
Command parameters: MiiNePort's Gateway address.
Reply parameters: N/A
?SNG192.168.1.254
!SNG0
Introduction to SCM (Serial Command Mode) Command Set
System sets NECI setting as 'Enable' for this MiiNePort.
MiiNePort reports command executed successfully.
System sets IP configuration as 'Static'.
MiiNePort reports command executed successfully.
System sets IP address as '192.168.1.2'.
MiiNePort reports command executed successfully.
System sets Netmask as '255.255.255.0'.
MiiNePort reports command executed successfully.
System sets Gateway as '192.168.1.254'.
MiiNePort reports command executed successfully.
A-17

Advertisement

Table of Contents
loading

Table of Contents