MiiNePort E2/E3
Data Packing Length
Command code: OL
Command parameters: Port index, MCSC channel index, and data packing length to set. Parameters are
separated by a semicolon (;). For an MCSC-disabled port, the channel index is 0.
Reply parameters: N/A
?SOL1;0;256
!SOL0
Delimiter
Command code: OD
Command parameters: Port index, MCSC channel index, delimiter1 enable/disable, delimiter character 1 by
hex, delimiter 2 enable/disable, and delimiter character 2 by hex. Parameters are separated by a semicolon (;).
For an MCSC-disabled port, the channel index is 0.
Reply parameters: N/A
?SOD1;2;1;10;1;13
!SOD0
Delimiter Process
Command code: OT
Command parameters: N/A
Reply parameters: Port index, MCSC channel index, and delimiter process. Parameters are separated by a
semicolon (;). For an MCSC-disabled port, the channel index is 0.
?SOT1;0;2
!SOT0
Force Transmit
Command code: OF
Command parameters: Port index, MCSC channel index, and force transmit timeout. Parameters are separated
by a semicolon (;). For an MCSC-disabled port, the channel index is 0.
Reply parameters: N/A
?SOF1;0;5
!SOF0
Real COM TCP alive check time
Command code: RA
Command parameters: Port index, MCSC channel index, and TCP alive check time. Parameters are separated
by a semicolon (;). For an MCSC-disabled port, the channel index is 0.
Reply parameters: N/A.
?SRA1;0;5
!SRA0
Introduction to SCM (Serial Command Mode) Command Set
System sets port 1's data packing length as '256'.
MiiNePort reports command executed successfully.
System sets channel 2 of port 1's delimiter 1 as 'Enable' and hex code as
'10'. Delimiter 2 as 'Enable' and hex code as '13'.
MiiNePort reports command executed successfully.
System sets port 1's delimiter process as 'Delimiter+2'.
MiiNePort reports command executed successfully.
System sets port 1's force transmit timeout as '5'.
MiiNePort reports command executed successfully.
System sets port 1's TCP alive check time as '5' for port 1.
MiiNePort reports command executed successfully.