MiiNePort E2/E3
Real COM TCP alive check time
Command code: RA
Command parameters: Two numbers separated by a semicolon (;) denote port index and MCSC channel index.
For an MCSC-disabled port, the channel index is 0.
Reply parameters: MiiNePort's TCP alive check time.
?GRA1;0
!GRA05
Real COM max connection
Command code: RM
Command parameters: Two numbers separated by a semicolon (;) denote port index and MCSC channel index.
For an MCSC-disabled port, the channel index is 0.
Reply parameters: MiiNePort's TCP maximum connection number.
?GRM1;1
!GRM04
Real COM Ignores Jammed IP
Command code: RJ
Command parameters: Two numbers separated by a semicolon (;) denote port index and MCSC channel index.
For an MCSC-disabled port, the channel index is 0.
Reply parameters: 1 (Enable) or 0 (Disable)
?GRJ1;2
!GRJ01
Real COM Allows Driver Control
Command code: RD
Command parameters: Two numbers separated by a semicolon (;) denote port index and MCSC channel index.
For an MCSC-disabled port, the channel index is 0.
Reply parameters: 1 (Enable) or 0 (Disable)
?GRD1;0
!GRD01
RFC2217 TCP alive check time
Command code: FA
Command parameters: Two numbers separated by a semicolon (;) denotes port index and MCSC channel index.
For MCSC-disabled port, channel index shall be 0.
Reply parameters: 1 (Enable) or 0 (Disable)
?GFA1;0↲
!GFA07↲
Introduction to SCM (Serial Command Mode) Command Set
System requests port 1's TCP alive check time for port 1.
MiiNePort reports TCP alive check time as '5' min.
System requests maximum connection number for port 1 and channel 1.
MiiNePort reports maximum connection number as '4'.
System requests jammed IP policy for port 1's channel 2.
MiiNePort reports ignore jammed IP as 'Enable'.
System requests allow driver control policy for port1.
MiiNePort reports allow driver control as 'Enable'.
System requests for alive check time for port1.
MiiNePort reports alive check time is '7'.