Moxa Technologies MiiNePort E2-H User Manual page 100

Miineport e2/e3
Hide thumbs Also See for MiiNePort E2-H:
Table of Contents

Advertisement

MiiNePort E2/E3
Flow control
Command code: SL
Command parameters: Port index.
Reply parameters: MiiNePort's Flow control index as follows.
0
None
1
RTS/CTS
2
XON/XOFF
3
DTR/DSR
?GSL1
!GSL01
FIFO
Command code: SF
Command parameters: Port index.
Reply parameters: 1 (Enable) or 0 (Disable) MiiNePort's FIFO.
?GSF1
!GSF01
Interface
Command code: SI
Command parameters: Port index.
Reply parameters: 0 (RS232) or 1 (RS485-2wire) MiiNePort's Interface.
?GSI1↲
!GSI01↲
Operation Mode
Command code: OM
Command parameters: Two numbers separated by a semicolon (;) denote port index and MCSC channel index.
For the port itself, channel index is 0.
Reply parameters: MiiNePort's operation mode index as shown in the following table.
0
Disable
1
Real COM
2
RFC2217
3
TCP server
4
TCP client
5
UDP
6
e-modem
7
MCSC (This value is unavailable for MCSC channels.)
?GOM1;0↲
!GOM04↲
?GOM1;2↲
!GOM02↲
Introduction to SCM (Serial Command Mode) Command Set
System requests port 1's Flow control for this MiiNePort.
MiiNePort reports Flow control as 'RTS/CTS'.
System requests port 1's FIFO for this MiiNePort.
MiiNePort reports FIFO as 'Enable'.
System requests for port 1's interface for this MiiNePort.
MiiNePort reports interface is 'RS485-2wire'.
System requests for port 1's Operation Mode for this MiiNePort.
MiiNePort reports Operation Mode is 'TCP client'.
When port 1 is set to MCSC, system requests for the operation mode for
channel 2 of port 1.
MiiNePort reports operation mode is ` RFC2217'.
A-8