G160 Service Manual
CMY Color Irregular Streaks
Symptom
Unexpected streaks of the
same color appear at irregular
intervals.
Ghosting
Symptom
The same or similar image
appears two or more times.
They get weaker and weaker.
Unfused or Partially Fused Prints
Symptom
Some parts of images are not
fused very well.
Possible cause
Defective PCU
Defective transfer belt unit
Possible cause
Defective PCU
Defective transfer unit
Possible cause
Non-standard paper in use
Incorrect media type mode
Defective fusing unit
50
23-Feb-06
Necessary actions
Replace the PCU.
Replace the transfer belt unit.
Necessary actions
Replace the PCU.
Replace the transfer unit.
Necessary actions
Use recommended paper.
Select an appropriate media
mode.
Replace the fusing unit.