[Forced Toner] Forced Toner Supply Execution
2252
2252 001
Repeat: [K]
2252 002
Repeat: [M]
2252 003
Repeat: [C]
2252 004
Repeat: [Y]
[Temp./Humidity] Temperature / Humidity Display
2302
2302 001
Temperature
2302 002
Relative Humidity
2302 003
Absolute Humidity
2302 004
Current Environ.
[Envir. Correct.] Environment Correction
2303
2303 001
Manual Correct.
[EC Threshold] Environment Correction Threshold
(Humidity, Environment) A. Humidity: Absolute Humidity
2304
These SPs adjust the thresholds (absolute humidity) for each environment.
2304 001
A. Humidity: LL-MM
2304 002
A. Humidity: ML-MM
2304 003
A. Humidity: MM-MH
2304 004
A. Humidity: MH-HH
[Vd Link Corre.] Vd Link Correction
2306
2306 001
Setting
2306 002
Correction Coef.
Adjusts the toner supply times for SP2251.
[0 to 30 / 8 / 1 time/step]
Displays the temperature.
[-128 to 127 / 0 / 0.1 deg/step]
Display the relative humidity.
[0 to 100 / 0 / 0.1%RH/step]
Display the absolute humidity.
[0 to 100 / 0 / 0.1 g/m
Display the current environment.
[0 to 4 / 0 / 1/step]
0: LL, 1: ML, 2: MM, 3: MH, 4: HH
Manually sets the environment.
*EGB
[0 to 5 / 0 / 1/step]
0: OFF, 1: LL, 2: ML, 3: MM, 4: MH, 5: HH
*EGB
[0 to 100 / 5.0 / 0.1 g/m
*EGB
[0 to 100 / 8.0 / 0.1 g/m
*EGB
[0 to 100 / 16.0 / 0.1 g/m
*EGB
[0 to 100 / 26.0 / 0.1 g/m
Sets the Vd link correction.
*EGB
[0 or 1 / 0 / -] Alphanumeric
0: Execute, 1: Not execute
*EGB
Adjusts the Vd link correction coefficient.
100
23-Feb-06
3
/step]
3
/step]
3
/step]
3
/step]
3
/step]