Ricoh G-P2 Service Manual page 40

Table of Contents

Advertisement

G160 Service Manual
SC
Symptom
[Level]
EGB data error
The data transfer in the EGB
690
is interrupted by some
[D]
incident (e.g. cover open
etc.) during the data transfer.
Controller Error
The following table shows the controller error codes. These codes show at these times if an
error occurs:
Power-on
After the power-on self diagnostic test
Always try turning the main switch off and on and check if the problem persists.
SC
Symptom
[Level]
636
SD Card Error
Expanded authentication module error
There is no expanded
authentication module in the
machine.
-001
The SD card or the file of the
[B]
expanded authentication
module is broken.
There is no DESS module in
the machine.
Version error
-002
The version of the expanded
[B]
authentication module is not
correct.
Possible Cause/Required Action
2.
Replace the controller board.
3.
Replace the EGB.
Defective EGB
1.
Replace the EGB.
Possible Cause/Required Action
No expanded authentication module
Defective SD card
No DESS module
1.
Install the expanded authentication
module.
2.
Install the SD card.
3.
Install the DESS module.
Incorrect module version
1.
Install the correct file of the expanded
authentication module.
33