Ricoh G-P2 Service Manual page 145

Table of Contents

Advertisement

G160 Service Manual
2968 004
RS [FC]: 2nd
2968 005
LS [K]: 1st
2968 006
LS [K]: 2nd
2968 007
LS [FC]: 1st
2968 008
LS [FC]: 2nd
[T2:HH:GL2] Transfer Roller Current: Correction for Humidity, HH
Environment, Glossary paper2,
(Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
2969
2969 001
RS [K]: 1st
2969 002
RS [K]: 2nd
2969 003
RS [FC]: 1st
2969 004
RS [FC]: 2nd
2969 005
LS [K]: 1st
2969 006
LS [K]: 2nd
2969 007
LS [FC]: 1st
2969 008
LS [FC]: 2nd
[T2:Size3] Transfer Roller Current: Correction for Humidity, Size3
2971
(Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
2971 001
LL/1st
2971 002
LL/2nd
2971 003
MM/1st
2971 004
MM/2nd
2971 005
HH/1st
2971 006
HH/2nd
SP3-XXX (Process)
[Vt Display] Vt Display ([Color])
3001
3001 001
[K]
*EGB
*EGB
*EGB
*EGB
*EGB
The value displayed on the LCD is different from these SP's values.
For example, "20%" on the LCD actually means 100%.
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
[0 to 1275 / P2a: 165, P2b: 125 / 5%/step]
[0 to 1275 / P2a: 135, P2b: 120 / 5%/step]
[0 to 1275 / P2a: 200, P2b: 120 / 5%/step]
[0 to 1275 / P2a: 225, P2b: 140 / 5%/step]
[0 to 1275 / P2a: 120, P2b: 135 / 5%/step]
[0 to 1275 / P2a: 135, P2b: 120 / 5%/step]
[0 to 1275 / 135 / 5%/step]
[0 to 1275 / P2a:170, P2b: 150 / 5%/step]
[0 to 1275 / P2a: 160, P2b: 165 / 5%/step]
[0 to 1275 / P2a: 200, P2b: 125 / 5%/step]
[0 to 1275 / 150 / 5%/step]
[0 to 1275 / P2a: 200, P2b: 185 / 5%/step]
[0 to 1275 / P2a: 165, P2b: 200 / 5%/step]
[0 to 100 / 100 / 1%/step]
[0 to 100 / 70 / 1%/step]
[0 to 100 / 100 / 1%/step]
[0 to 100 / P2a: 75, P2b: 60 / 1%/step]
[0 to 100 / 100 / 1%/step]
[0 to 100 / P2a: 80, P2b: 65 / 1%/step]
Displays the output voltage of TD sensor
138
23-Feb-06

Advertisement

Table of Contents
loading

This manual is also suitable for:

G161G160

Table of Contents