data, but only if one of the following conditions occurs.
At a set time after the previous adjustment. The default value is 360 minutes. You can
adjust the time with SP 2153 13.
When the temperature changed after a previous adjustment by more than a set value.
The default value is "5°C". You can adjust the temperature change value with SP 2153
12.
When the magnification changed after a previous adjustment by more than a set value.
The default value is "1%". You can adjust the magnification change value with SP 2153
15.
Interrupt
If SP 2153 5 is set to "1 (Yes)", then the adjustment is done when the one of the following
conditions occurs during a print job with many pages.
When the number of printed pages after the previous adjustment becomes more than a
set number. The number of pages includes black and color printing. The default value is
190 pages. (If this condition occurs, automatic line position adjustment after the next
interval process control will not be cancelled.) You can adjust the default value with SP
2153 10.
When the temperature changed after a previous adjustment by more than a set value.
The default value is "5°C". You can adjust the temperature change value with SP 2153
12.
When the magnification changed after a previous adjustment by more than a set value.
The default value is "1%". You can adjust the magnification change value with SP 2153
15.
243
23-Feb-06