[OHP: [K]: TE] Transfer roller current and discharge plate voltage correction for
2623
the trailing edge area of OHP in B/W mode
2623 002
Transfer Roller2
2623 003
Separation
[Switch Timing] Switch timing from normal to trailing edge, OHP
2624
(Paper Type, Edge) Paper Type -> OHP, TE: Trailing Edge
2624 002
T. Roll 2: OHP: TE
2624 003
Separa.: OHP: TE
[OHP: [FC]: LE] Transfer roller current and discharge plate voltage correction
2626
for the leading edge area of OHP in color mode
2626 002
Transfer Roller2
2626 003
Separation
[OHP: [FC]: TE] Transfer roller current and discharge plate voltage correction
2628
for the trailing edge area of OHP in B/W mode
2628 002
Transfer Roller2
2628 003
Separation
[Thin: [K]] Transfer roller current and discharge plate voltage for the image
area of thin paper in B/W mode
2631
Unit -> T.Roll2: Transfer roller, Separa.: Discharge plate (paper separation)
2631 007
Transfer Roller 2
2631 008
Separation
[Thin: [K]] Transfer roller current and discharge plate voltage for the image
2633
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different
from these SP's values. For example, "20%"
*EGB
on the LCD actually means 100%.
*EGB
[0 to 200 / 10 / 1 mm/step]
*EGB
[0 to 200 / 30 / 1 mm/step]
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different
from these SP's values. For example, "20%"
*EGB
on the LCD actually means 100%.
*EGB
[0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different
from these SP's values. For example, "20%"
*EGB
on the LCD actually means 100%.
Adjusts the transfer roller current.
*EGB
[0 to 60 / 30.0 / 0.1 -µA /step]
Adjusts the discharge plate voltage.
*EGB
[0 to 4 / 2.0 / 0.1 -KV/step]
117