G160 Service Manual
[Trans.Belt Bias] Transfer Belt Current at Process Control
2314
2314 011
Process Cont. [K]
2314 012
Process Cont. [M]
2314 013
Process Cont. [C]
2314 014
Process Cont. [Y]
[T.Roll2 Clean.] Transfer Roller Cleaning
(Positive or Negative Bias, Process Speed) Process Speed -> RS: Regular
2326
speed, LS: Low speed
2326 002
Posi. Bias: RS
2326 003
Posi. Bias: LS
2326 005
Nega. Bias: RS
2326 006
Nega. Bias: LS
[Trans.Belt Bias] Transfer Belt Current
2352
([Color], Process Speed) Process Speed -> RS: Regular speed
2352 001
[K]: RS
[Trans.Belt Bias] Transfer Belt Current
2353
([Color], Process Speed) Process Speed -> LS: Low speed
2353 001
[K]: LS
[1.00 to 2.50 / 1.00 / 0.01/step]
Adjusts the transfer belt current at process
*EGB
control for [K].
[0 to 60 / P2a 15.0, P2b: 13.0 / 0.1 µA /step]
*EGB
Adjusts the transfer belt current at process
control for [M, C].
*EGB
[0 to 60 / P2a 12.5, P2b: 10.0 / 0.1 µA /step]
Adjusts the transfer belt current at process
*EGB
control for [Y].
[0 to 60 / P2a 12.5, P2b: 13.0 / 0.1 µA /step]
*EGB
Adjusts the positive voltage for transfer roller
cleaning.
*EGB
[0 to 2 / 2.0 / 0.1 KV/step]
*EGB
Adjusts the negative voltage for transfer roller
cleaning.
*EGB
[0 to 60 / 60.0 / 0.1V/step]
Adjusts the current that is applied to the
transfer belt.
[0 to 60 / P2a 15.0, P2b: 17.0 / 0.1 µA /step]
Adjusts the current that is applied to the
*EGB
transfer belt.
[0 to 60 / P2a 6.0, P2b: 7.5 / 0.1 µA /step]
101