G160 Service Manual
9910 021
MUSIC Vsg Adj.
9911
[TC Initial]
9911 001
Maximum Repeat
9911 002
Threshold
9912
[ST Sensor]
9912 001
read
[Waste Toner NF] Waste Toner Near Full
9914
Specifies the number of sheets to be printed after waste toner near full.
9914 001
Print 1
9914 002
Print 2
9914 003
Print 3
9914 004
Print 4
9914 005
Detection Times
9914 006
Near Full Count.
[LD Pow. Change] LDB Power Change
9918
[0 to 5/ 3 / 1 /step]
Selects the Vsg adjustment execution when
the line position adjustment is manually done.
[1 to 3 / 3 / 1 /step]
*EGB
1: Normal (ON except the line position
adjustment at printout interval)
2: Always ON
3: Always OFF
Adjusts the maximum toner cartridge
*EGB
initializing time.
[1 to 30 / 15 / 1 /step]
Adjusts the threshold for toner cartridge
*EGB
initializing.
[1 to 100 / 20 / 0.01 V/step]
*EGB
Adjusts the Vcnt. DFU
*EGB
[0 to 5000 / 1250 / 1/step]
*EGB
[0 to 5000 / 250 / 1/step]
*EGB
[0 to 5000 / 125 / 1/step]
Specifies the number of sheets to be printed
*EGB
after replacing the waste toner bottle.
[0 to 5000 / 2500 / 1/step]
Displays the times of waste toner near full.
*EGB
[0 to 50 / 0 / 1 /step]
Displays the total counter for waste toner near
*EGB
full.
[0 to 100000 / 0 / 1 /step]