G160 Service Manual
2186 007
Result
2186 008
Execution
2186 009
Failure
[MUSIC Result] Automatic Line Position Adjustment Result
The following SPs display the skew adjustment values after the line position
2187
adjustment have been done.
2187 001
[K]:Skew Adj.
2187 002
[M]:Skew Adj.
2187 003
[C]:Skew Adj.
2187 004
[Y]:Skew Adj.
[Charge Bias: DC] Charge Roller Voltage: DC
(Process Speed, [Color]) Process Speed LS: Low speed, RS: Regular speed
2201
These SPs adjust the DC voltage of the drum charge roller. These are used
only when SP3-501-001 is set to "1".
2201 001
RS: [K]
2201 002
RS: [M]
2201 003
RS: [C]
2201 004
RS: [Y]
2201 006
LS: [K]
2201 007
LS: [M]
2201 008
LS: [C]
2201 009
LS: [Y]
[Charge Bias: AC] Charge Roller Voltage: AC
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular
speed
2202
These SPs adjust the AC voltage of the drum charge roller. These are used only
when SP2-202-011 is set to "1".
2202 001
RS: [K]
2202 002
RS: [M]
2202 003
RS: [C]
2202 004
RS: [Y]
*EGB
[0 to 999999 / 0 / 1 /step]
*EGB
[0 to 9999 / 0 / 1 /step]
*EGB
[0 to 9999 / 0 / 1 /step]
*EGB
*EGB
[-99 to 99 / 0 / 1 click/step]
*EGB
*EGB
*EGB
*EGB
*EGB
*EGB
[200 to 999 / 585 / 1 V/step]
*EGB
*EGB
*EGB
*EGB
*EGB
[0 to 3000 / 2000 / 1 V/step]
*EGB
*EGB
*EGB
97