G160 Service Manual
3011 007
TD Target: [C]
3011 008
TD Target: [Y]
[Vt Shift] Vt Shift Setting ([Color])
3021
3021 001
[K]
3021 002
[M]
3021 003
[C]
3021 004
[Y]
3032
[Vcnt Response] DFU
3032 001
[K]
3032 002
[M]
3032 003
[C]
3032 004
[Y]
3032 005
Max
3032 006
Min
[Vtref] Vtref Setting ([Color])
3041
3041 001
Lower Limit: [K]
3041 002
Lower Limit: [M]
3041 003
Lower Limit: [C]
3041 004
Lower Limit: [Y]
3041 005
Upper Limit: [K]
3041 006
Upper Limit: [M]
3041 007
Upper Limit: [C]
3041 008
Upper Limit: [Y]
[Vtref] Vtref Correction Setting ([Color]) DFU
3042
3042 001
Mode
*EGB
[0.00 to 5.00 / 2.80 / 0.01 V/step]
*EGB
*EGB
Adjusts the Vt shift rate for each color.
*EGB
[0.00 to 5.00 / P2a: 0.75, P2b: 0.90 / 0.01
*EGB
V/step]
*EGB
*EGB
Adjusts the Vcnt correction coefficient for each
*EGB
color.
*EGB
[1.00 to 5.00 / 3.71 / 0.01 V/step]
*EGB
Adjusts the maximum Vcnt correction
*EGB
coefficient.
[1.00 to 5.00 / 4.30 / 0.01 V/step]
Adjusts the minimum Vcnt correction
*EGB
coefficient.
[1.00 to 5.00 / 3.50 / 0.01 V/step]
*EGB
Sets the lower limit Vtref voltage for each
*EGB
color.
*EGB
[0.10 to 5.00 / 1.50 / 0.01 V/step]
*EGB
*EGB
DFU
*EGB
Sets the maximum limit Vtref voltage for each
color.
*EGB
[0.10 to 5.00 / 3.70 / 0.01 V/step]
*EGB
Sets the Vtref correction.
*EGB
[0 or 1 / 1 / -] Alphanumeric