Ricoh G-P2 Service Manual page 148

Table of Contents

Advertisement

G160 Service Manual
3042 002
Step [K]
3042 003
Step [M]
3042 004
Step [C]
3042 005
Step [Y]
3042 006
Adj. Remain: [K]
3042 007
Adj. Remain: [M]
3042 008
Adj. Remain: [C]
3042 009
Adj. Remain: [Y]
3042 014
Change Step: [K]
3042 015
Change Step: [M]
3042 016
Change Step: [C]
3042 017
Change Step: [Y]
[Vt Thr.Setting] Vt Threshold Setting ([Color])
3051
3051 001
Low Vt Thr.:[K]
3051 002
Low Vt Thr.:[M]
3051 003
Low Vt Thr.:[C]
3051 004
Low Vt Thr.:[Y]
3051 005
High Vt Thr.:[K]
3051 006
High Vt Thr.:[M]
3051 007
High Vt Thr.:[C]
3051 008
High Vt Thr.:[Y]
[P. Sensor Patt.] ID Sensor Pattern Setting ([Color])
3101
3101 001
Change Value: [K]
3101 002
Change Value: [M]
3101 003
Change Value: [C]
3101 004
Change Value: [Y]
[P. Sensor Patt.] ID Sensor Pattern Setting ([Color])
3102
3102 001
Change Value: [K]
3102 002
Change Value: [M]
3102 003
Change Value: [C]
0: On, 1: Off
*EGB
Adjusts the Vtref correction step for each
*EGB
color.
*EGB
[0.00 to 1.00 / 0.10 / 0.01 V/step]
*EGB
Displays the remaining Vtref value for each
color.
[-5.00 to 5.00 / - / 1 V/step]
*EGB
Adjusts the density change rate of the ID
*EGB
sensor pattern for each color.
*EGB
[0 to 100 / 15 / 1%/step]
*EGB
*EGB
Sets the threshold of the lower limit Vt voltage
*EGB
for each color.
*EGB
[0.10 to 5.00 / 2.00 / 0.01 V/step]
*EGB
*EGB
DFU
*EGB
Sets the threshold of the upper limit Vt voltage
*EGB
for each color.
[0.10 to 5.00 / 3.00 / 0.01 V/step]
*EGB
*EGB
Displays the density change rate of the ID
*EGB
sensor pattern for each color.
*EGB
[-100 to 100 / 0 / 1%/step]
*EGB
*EGB
Displays the toner amount change of the ID
sensor pattern for each color.
*EGB
[-1.000 to 1.000 / 0 / 0.001 mg/cm
*EGB
141
23-Feb-06
2
/step]