115200
230400
460800
921600
2900000
3000000
NOTES
1.
If a fixed baud rate is set, make sure that both TE (DTE, usually external processor) and TA (DCE,
Quectel module) are configured to the same rate.
2.
The value of AT+IPR cannot be restored with AT&F and ATZ; but it is still storable with AT&W.
3.
In multiplex mode, the baud rate cannot be changed by the Write Command AT+IPR=<rate>; and
the setting is invalid and cannot be stored even if AT&W is executed after the Write Command.
4.
A selected baud rate takes effect after the Write Commands are executed and acknowledged by OK.
Example
AT+IPR=115200
OK
AT&W
OK
AT+IPR?
+IPR: 115200
OK
AT+IPR=115200;&W
OK

3.6. AT+QRIR Restore RI Behavior to Inactive

If the RI (ring indicator) behavior is "always", it can be restored to inactive by the Execution Command.
The
RI
behavior
AT+QCFG="urc/ri/smsincoming" and AT+QCFG="urc/ri/other" for more details.
AT+QRIR Restore RI Behavior to Inactive
Test Command
AT+QRIR=?
Execution Command
AT+QRIR
EC25&EC21_AT_Commands_Manual
is
controlled
by
AT+QCFG.
Response
OK
Response
OK
EC25&EC21 AT Commands Manual
//Set fixed baud rate to 115200bps
//Store current setting, that is, the serial communication
speed is 115200bps after restarting module
//Set fixed baud rate to 115200bps and store current setting
Please
LTE Module Series
refer
to
AT+QCFG="urc/ri/ring",
35 / 231

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec21

Table of Contents