<Maximum bitrate UL>
<Maximum bitrate DL>
<Guaranteed bitrate UL>
<Guaranteed bitrate DL>
<Delivery order>
<Maximum SDU size>
<SDU error ratio>
EC25&EC21_AT_Commands_Manual
4
Subscribed value
Integer type. Indicates the maximum number of kbits/s delivered to
UMTS (up-link traffic) at a SAP. As an example a bit rate of 32kbit/s
would be specified as „32‟ (e.g. AT+CGEQREQ=...,32, ...).
0
Subscribed value
1~5760
Integer type. Indicates the maximum number of kbits/s delivered by
UMTS (down-link traffic) at a SAP. As an example a bitrate of 32kbit/s
would be specified as „32‟ (e.g. AT+CGEQREQ=...,32, ...).
0
Subscribed value
1~42200
Integer type. Indicates the guaranteed number of kbits/s delivered to
UMTS (up-link traffic) at a SAP (provided that there is data to deliver).
As an example a bitrate of 32kbit/s would be specified as „32‟ (e.g.
AT+CGEQREQ=...,32, ...).
0
Subscribed value
1~5760
Integer type. Indicates the guaranteed number of kbits/s delivered by
UMTS (down-link traffic) at a SAP (provided that there is data to
deliver). As an example a bitrate of 32kbit/s would be specified as „32‟
(e.g. AT+CGEQREQ=...,32, ...).
0
Subscribed value
1~42200
Integer type. Indicates whether the UMTS bearer shall provide
in-sequence SDU delivery or not (refer to 3GPP TS 24.008 subclause
10.5.6.5).
0
No
1
Yes
2
Subscribed value
Integer type. (1,2,3,...) indicates the maximum allowed SDU size in
octets. If the parameter is set to „0‟ the subscribed value will be
requested (refer to 3GPP TS 24.008 subclause 10.5.6.5).
0
Subscribed value
10...1520
(Value needs to be divisible by 10 without remainder)
1520
String type. Indicates the target value for the fraction of SDUs lost or
detected as erroneous. SDU error ratio is defined only for conforming
traffic. The value is specified as „mEe‟. As an example a target SDU
error
ratio
of
5*10
AT+CGEQREQ=...,"5E3",...).
"0E0"
Subscribed value
"1E1"
"1E2"
"7E3"
EC25&EC21 AT Commands Manual
-3
would
be
specified
LTE Module Series
as
"5E3"
(e.g.
156 / 231