Quectel EC25 Command Manual page 162

Lte module series, at commands
Hide thumbs Also See for EC25:
Table of Contents

Advertisement

<SDU error ratio>
<Residual bit error ratio>
<Delivery of erroneous SDUs> Integer type. Indicates whether SDUs detected as erroneous shall be
<Transfer delay>
<Traffic handling priority>
EC25&EC21_AT_Commands_Manual
String type. Indicates the target value for the fraction of SDUs lost or
detected as erroneous. SDU error ratio is defined only for conforming
traffic. The value is specified as „mEe‟. As an example a target SDU
error
ratio
of
5*10
AT+CGEQREQ=...,"5E3",...).
"0E0"
Subscribed value
"1E2"
"7E3"
"1E3"
"1E4"
"1E5"
"1E6"
"1E1"
String type. Indicates the target value for the undetected bit error ratio
in the delivered SDUs. If no error detection is requested, Residual bit
error ratio indicates the bit error ratio in the delivered SDUs. The value
is specified as "mEe". As an example a target residual bit error ratio of
5•10-3
would
AT+CGEQREQ=...,"5E3",...).
"0E0"
Subscribed value
"5E2"
"1E2"
"5E3"
"4E3"
"1E3"
"1E4"
"1E5"
"1E6"
"6E8"
delivered or not (refer to 3GPP TS 24.008 subclause 10.5.6.5).
0
No
1
Yes
2
No detect
3
Subscribed value
Integer type. (0,1,2,...) indicates the targeted time between request to
transfer an SDU at one SAP to its delivery at the other SAP, in
milliseconds. If the parameter is set to „0‟ the subscribed value will be
requested (refer to 3GPP TS 24.008 subclause 10.5.6.5).
0
Subscribed value
100~150
(value needs to be divisible by 10 without remainder)
200~950
(value needs to be divisible by 50 without remainder)
1000~4000 (value needs to be divisible by 100 without remainder)
Integer type. (1,2,3,...) specifies the relative importance for handling of
EC25&EC21 AT Commands Manual
-3
would
be
specified
specified
be
LTE Module Series
as
"5E3"
(e.g.
as
"5E3"
(e.g.
161 / 231

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec21