Table 13-4 Enhanced control interface
Address
Byte 3
y

Mode of Operation: Preset of a sensitivity/distance value (IntelliTeach)

Figure 13-6
ET 200S Distributed I/O System
EWA-4NEB 780602402-12
Assignment
Set sensitivity/distance value at channel 3
y
Bit 0:
1: Sensitivity/distance value transferred to
1: Sensitivity/distance value transferred to
sensor on channel 3
sensor on channel 3
( y
(by rising edge)
g
g )
0: disabled
di
bl d
Bit 1 to bit 7:
Bit 1 to bit 7:
sensitivity/distance value
sensitivity/distance value
at channel 3 1 to 126 (sensor-dependent)
Teach-in at sensor channel 3
Bit 0:
1: Start Teach-in at sensor channel 3 (by
rising edge)
0: disabled
Bit 1 to bit 7: 0
Standard mode
(valid sensitivity/
distance value)
Preset sensitivity/distance
value (1 to 126)
at bit 1 to 7 in the PIQ
Sensitivity/distance value
transferred to sensor by rising
edge
at bit 0 in the PIQ
Mode of Operation: Preset of a sensitivity/distance value (IntelliTeach)
4 IQ-SENSE
Designation on
"IQ-SENSE Opto"
function block
WR_TEACH_VAL
TEACH_VAL_IN
TEACH VAL IN
START_TEACH
13-13