Response Times
Response time
The response time (t
output values in internal memory until the specified value is obtained at the analog
output -- is, in the most unfavorable case, the sum of the cycle time and the settling
time. The most unfavorable case is when the analog channel is converted shortly
before the transfer of a new output value and is not converted again until after the
conversion of the other channels (cycle time).
Fig. D-7 shows the response time of an analog output channel.
Figure D-7
D.7
Response times for a 4 IQ-SENSE electronic module
The response time of the 4 IQ-SENSE electronic module is specified as a cycle
time in the technical specifications.
D.8
Response times for process-related modules
The response times of the process-related modules are indicated as response time
or update rate in the technical specifications. See the ET 200S Process-Related
Functions manual
D-8
to t
) -- that is, the time from the application of the digital
1
3
t
A
t
C
t
t
2
1
t
= response time
A
t
= cycle time according to the processing time of the module and
C
conversion time of the channel
t
= settling time
I
t
= a new digital output value is queued
1
t
= output value accepted and processed
2
t
= specified output value reached
3
Response time of an analog output channel
t