Siemens SIMATIC ET 200S Manual page 475

Distributed i/o system
Hide thumbs Also See for SIMATIC ET 200S:
Table of Contents

Advertisement

Analog Value Formation
Measurement principle
Integration and cycle time /
resolution per channel:
Integration time
selectable
Interference frequency
suppression in Hz
Integration time in ms
Conversion time in ms
Cycle time in ms
Resolution (incl.
overshoot range)
Interference Suppression, Error Limits
Interference voltage sup-
pression for f= n x (f11%),
(f1 = interference frequen-
cy)
Common mode
interference
(peak value of
interference < rated
value of the input range)
Crosstalk between inputs
ET 200S Distributed I/O System
EWA-4NEB 780602402-12
integrating
Yes
60
50
16,7
20
55
65
Number of active
channels per
module
¢
conversion time
20 mA/13 Bit + VZ
¦
4 to 20 mA/13 bits
min. 70 dB
min. -- 50 dB
Analog Electronic Modules
Operational error limits
(across the temperature
range, in relation to input
range)
Basic error limit (operational
error limit at 25 _C, related
to the input range)
Temperature error (in rela-
tion to input range)
Linearity error (relative to
the input range)
Repetition accuracy
(in transient state at 25 _C,
relative to input range)
Data for selection of the sensor
Input range (rated
value)/input resistance
Current
Permitted continuous input
current (destruction limit)
Smoothing of measured
values
Level
weak
medium
strong
0.6 %
0.4 %
0.005 %/K
0.01 %
0.05 %
20 mA/50 Ω
4 to 20 mA/50 Ω
40 mA
Yes, configurable in
4 stages by digital
filtering
Time constant
No
1 x cycle time
4 x cycle time
32 x cycle time
64 x cycle time
12-69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents