Terminal Assignment Of The 2Do 24 Vdc/0.5 A Standard - Siemens SIMATIC ET 200S Manual

Distributed i/o system
Hide thumbs Also See for SIMATIC ET 200S:
Table of Contents

Advertisement

Digital Electronic Modules
Special feature
When the rated load voltage of 24 VDC is connected at the power module via a
mechanica contact, the digital outputs carry a "1" signal for approx. 50 µs because
of the circuit type. This must be considered when the module is connected to fast
counters.
Connection assignment
The following table shows the terminal assignment of the 2DO 24 VDC/0.5 A
Standard for the various terminal modules:
Table 11-19 Terminal assignment of the 2DO 24 VDC/0.5 A Standard
View
TM-E15S24-A1 and 2DO 24 VDC/o.5 A Standard
CH0
DO
0
1
VDC
2
M
3
AUX1 (e.g. PE)
A
A
4
TM-E15S24-01 and 2DO 24 VDC/0.5 A Standard
CH0
DO
1
0
VDC
2
M
3
n. c.
4
11-48
CH1
2-wire
DO
1
5
VDC
6
M
7
AUX1 (e.g. PE)
8
AUX1 must be occupied
with 4 wires at PE.
CH1
2-wire
DO
5
1
VDC
6
M
7
n. c.
8
Terminal assignment
3-wire
4-wire
3-wire
Remarks
Channel 0:
Terminals 1 to A4
Channel 1:
Terminals 5 to A8
DO: Output signal
(max. 0.5 A per channel)
24 VDC: Sensor supply
M : Load power supply
ground
Channel 0: Terminals 1 to 4
Channel 1: Terminals 5 to 8
DO: Output signal
(max. 0.5 A per channel)
24 VDC: Sensor supply
M : Load power supply
ground
Terminals 4 and 8 can be
used for connection of
cables that are not required
u to 30 VDC.
ET 200S Distributed I/O System
EWA-4NEB 780602402-12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents