Digital Electronic Modules
Connection assignment
The following table shows the terminal assignment of the 2DI 24 VDC High
Feature for the various terminal modules:
Table 11-7 Terminal assignment of the 2DI 24 VDC High Feature
View
CH0
DI
0
1
VDC
2
M
3
A
AUX1 (e.g. PE)
4
CH0
DI
0
1
VDC
2
M
3
n. c.
4
CH0
DI
0
1
VDC
2
M
3
11-20
TM-E15S24-A1 and 2DI 24 VDC Standard
CH1
2-wire
DI
1
5
VDC
6
M
7
A
AUX1 (e.g. PE)
8
TM-E15S24-01 and 2DI 24 VDC High Feature
CH1
2-wire
DI
1
5
VDC
6
M
7
n. c.
8
TM-E15S23-01 and 2DI 24 VDC High Feature
CH1
2-wire
DI
1
5
VDC
6
M
7
Terminal assignment
3-wire
4-wire
AUX1 must be occupied
with 4 wires at PE.
3-wire
3-wire
Remarks
Channel 0:
Terminals 1 to A4
Channel 1:
Terminals 5 to A8
DI: Input signal
24 VDC: Sensor supply
M : Chassis ground
Channel 0: Terminals 1 to 4
Channel 1: Terminals 5 to 8
DI: Input signal
24 VDC: Sensor supply
M : Chassis ground
Terminals 4 and 8 can be
used for connection of
cables that are not required
up to 30 VDC.
Channel 0: Terminals 1 to 4
Channel 1: Terminals 5 to 8
DI: Input signal
24 VDC: Sensor supply
M : Chassis ground