Analog Electronic Modules
Analog Value Formation
Resolution (incl. overshoot
range)
Cycle time
Settling time
For resistive load
For capacitive load
For inductive load
Substitute value configur-
able
Interference Suppression, Error Limits
Crosstalk between outputs
Operational error limits
(across the temperature
range, in relation to output
range)
Basic error limit (operational
error limit at 25 _C, related
to the output range)
Temperature error (in rela-
tion to output range)
Linearity error (in relation to
output range)
Repetition accuracy
(in transient state at 25 _C,
relative to output range)
12-102
10 V/ 13 Bit + VZ
¦
1 to 5 V/12 bits
Max. 1.5 ms
0.1 ms
0.5 ms
0.5 ms
Yes
min. --40 dB
0.4 %
0.2 %
0.01 %/K
0.02 %
0.05 %
Output ripple (in relation to
output range, bandwidth 0
to 50 kHz)
Data for selection of the actuator
Output range (nominal
value)
Load resistance
For capacitive load
Short-circuit protection
Short-circuit current
Destruction limit for exter-
nally applied voltages/cur-
rents
Voltage measured
between the outputs
and M
ANA
Current
Connection of actuators
2-wire connection
4-wire connection
ET 200S Distributed I/O System
0.02 %
 10 V
1 to 5 V
Min. 1.0 kΩ
max. 1 µF
Yes
Approx. 25 mA
Max. 15 V
continuous, 75 V for
max. 1 s (sampling
ratio 1:20)
max. DC 50 mA
Possible, without
compensation of
cable resistance
Yes
EWA-4NEB 780602402-12