4 IQ-SENSE
Order number
6ES7 138-4GA00-0AB0
Features
The 4 IQ-SENSE has the following features:
• Connection of sensors with IQ-SENSE
reflection light barriers, reflection light and laser probes.
• Up to 4 sensors can be connected to every module. One 2-wire cable is
required per sensor.
• Function reserve and monitoring
• Configurable time functions, differential travel, synchronization groups
• Specification of sensitivity and distance values (IntelliTeach via FB "IQ-SENSE
Opto")
• Teach-in
• Removal and insertion of module during operation (restart of Teach-in via
"IQ-SENSE Opto" function module or button on sensor required)
• Removal and insertion of sensors during operation (automatic reconfiguration)
• Supports sensors with alignment assistance
• The 4 IQ-SENSE is a single-width (15 mm) electronic module and can be used
with the following terminal modules:
-- TM-E15S24-01, TM-E15C24-01 or TM-E15N24-01
-- TM-E15S26-A1, TM-E15C26-A1 or TM-E15N26-A1
Parameter assignment
The parameters for the 4 IQ-SENSE are configured with the STEP7.
STEP 7 as of V5.1, ServicePack 3
Included in the hardware catalog of
HWConfig A GSD file is not required.
13-2
, photo-electric proximity switches: e.g.
R
Configuration rules
STEP 7 as of V5.0, ServicePack 3 or other
configuration software
IM151-1 BASIC: GSD file SIEM80F3.GSx as
of 09/02 (from V1.0)
IM151-1 STANDARD: GSD file
SIEM806A.GSx as of 10/01 (from V1.10)
IM151-1 FO STANDARD: GSD file
SIEM806B.GSx as of 10/01 (from V1.5)
IM151-1 HIGH FEATURE: GSD file
SIR380E0.GSx as of 12/01 (from V1.0)