7. Press the spacebar to change the field from On to Off.
Note
Changing the Do Not Disturb option enables the token programming residing in the
Extension field of the mailbox. It is the token string in this mailbox that performs the
shutdown procedure.
8. Press Alt+S to save the changes.
To shut down the Stratagy using the telephone dial pad
1. From the telephone dial pad, call Stratagy. Once you dial into Stratagy, the system answers with
the standard company greeting. Stratagy prompts you to enter the User ID.

2. Enter
. Stratagy prompts you to enter the security code.
Important!
You must wait until the entire prompt has been played before entering the security
code. If the code is entered prior to the completion of the prompt, the shutdown does
not occur.
3. Enter the new security code (the default is
taken off-hook. All active channels are given a 60 second time delay to complete processing the
current activity. After 60 seconds, they are disconnected and the system shuts down.
The Stratagy is completely shut down when the status light is Out and all port LEDs are On.
Note
For security reasons, you should change the default security code.
Important!
Shutdown Using the Stratagy Admin's Main Menu
1. From Stratagy Admin's Main Menu, select Shutdown by pressing Alt+s. Stratagy asks for the
password.
2. Enter the password (the default is Stratagy) and press Enter. The screen enables you to
select one of the following options:
Shutdown and Restart CURRENT Version — Restarts Stratagy.
This option must be used any time you make significant programming changes (see
Note
"Automatic System Recovery" on page 11-14
Shutdown and Trace CURRENT Version — Shuts down, then restarts Stratagy in the
TRACE mode (TRACE.OUT file is created) on Stratagy's flash drive. See
11-12
for details.
Shutdown and Start NEW Version — Shuts down, then restarts Stratagy using the new
database and new Stratagy system software, if any.
Shutdown and Start OLD Version — Shuts down, then restarts Stratagy using the software
version previous to the upgraded software.
Shutdown, SCANDISK, and Restart — Shuts down, runs ScanDisk program and then
restarts Stratagy.
Note
There is no screen interaction during the running of the ScanDisk Utility.
Shutdown and STOP for power off — Takes Stratagy off-line and does not restart it.
Stratagy I&M
06/02

) and press . All inactive channels are
for details).