Toshiba Stratagy IVP8 Installation And Maintenance Manual page 81

Voice processing systems
Hide thumbs Also See for Stratagy IVP8:
Table of Contents

Advertisement

Parameter
console_slot_id
daylight_saving_time
db_locking
Stratagy I&M
06/02
Identifies to IVP8 the physical slot in the Strata DK that contains the PDKU
programmed for DSS console in Program 03 (type 64). The IVP8 monitors this slot
for the busy lamp field (see dss_active parameter), and Night Transfer.
For Strata DK40i/DK40/DK16e/DK16 and DK24, DK56, and DK96: the
console_slot_id is always set to 0 (zero). Slot ID 0 corresponds to card slot S11 for
DK40i/DK40/DK16e/DK16 or slot 01 for DK24, DK56, and DK96.
CAUTION!
For Strata DK16: If this parameter is set to 1, IVP8 is disabled. All
ports return "ring no answer" when dialed.
For Strata CTX100/CTX670, DK424i/DK424 and DK280: set this parameter per
the following table.
CTX100/CTX670
DK424i/DK424/DK280 Slot Assignment
11, 31, 51
12, 32, 52
13, 33, 53
14, 34, 54
15, 35, 55
16, 36, 56
Important!
For this feature to work, the PDKU must reside in an odd numbered
cabinet (see
Figure 2-1
In all applications, the IVP8 must reside in a higher-numbered slot in
the same cabinet or next even numbered cabinet as the PDKU card
(defined as console_slot_id).
Possible values: 0~5
Default: 0 (zero)
Resets Stratagy's system time to daylight savings time.
Note The current setting is displayed at the top right corner of the Main Menu.
True:
Stratagy sets the system automatically to daylight savings time at 2:00
a.m. the first Sunday in April and the last Sunday in October.
False:
Stratagy does not reset system time and continues with standard time
(Stratagy clock).
Important!
(IVP8 only) Setting the ksu_time parameter to true disables this
setting.
Possible values: true, false
Default: true
Locks a database's records before Stratagy reads them.
True:
Stratagy tries to lock a database's records before reading them (read
only).
False:
Stratagy does not lock the database's records.
Possible values: true, false
Default: false