Daikin MicroTech II Installation And Maintenance Manual page 93

Chiller unit controller
Table of Contents

Advertisement

Alarm
Class Description
82
F
COMPRESSOR SHUTDOWN - Overvoltage #3
84
F
COMPRESSOR SHUTDOWN - Undervoltage #1
85
F
COMPRESSOR SHUTDOWN - Undervoltage #2
86
F
COMPRESSOR SHUTDOWN - Undervoltage #3
88
F
COMPRESSOR SHUTDOWN - Condenser Pressure Sensor Fault
COMPRESSOR SHUTDOWN - Condenser Pressure Sensor Fault
89
F
#1
COMPRESSOR SHUTDOWN - Condenser Pressure Sensor Fault
90
F
#2
COMPRESSOR SHUTDOWN - Condenser Pressure Sensor Fault
91
F
#3
93
F
COMPRESSOR SHUTDOWN - Condenser Water Flow Loss
94
F
COMPRESSOR SHUTDOWN - Condenser Pressure High
95
F
COMPRESSOR SHUTDOWN - Condenser Pressure High #1
96
F
COMPRESSOR SHUTDOWN - Condenser Pressure High #2
97
F
COMPRESSOR SHUTDOWN - Condenser Pressure High #3
99
F
COMPRESSOR OFF - Current High with Compressor OFF #1
100
F
COMPRESSOR OFF - Current High with Compressor OFF #2
COMPRESSOR SHUTDOWN - Discharge Temperature Sensor
103
F
Fault #1
COMPRESSOR SHUTDOWN - Discharge Temperature Sensor
104
F
Fault #2
COMPRESSOR SHUTDOWN - Discharge Temperature Sensor
105
F
Fault #3
107
F
COMPRESSOR SHUTDOWN - Discharge Temperature High #1
108
F
COMPRESSOR SHUTDOWN - Discharge Temperature High #2
109
F
COMPRESSOR SHUTDOWN - Discharge Temperature High #3
COMPRESSOR SHUTDOWN - Condenser Entering Water
111
F
Temperature Sensor Fault
112
F
COMPRESSOR SHUTDOWN - Evaporator Water Flow Loss
COMPRESSOR SHUTDOWN - Evaporator Leaving Water
113
F
Temperature Low (Freeze)
114
F
COMPRESSOR SHUTDOWN - Evaporator Pressure Low
115
F
COMPRESSOR SHUTDOWN - Evaporator Pressure Low #1
116
F
COMPRESSOR SHUTDOWN - Evaporator Pressure Low #2
117
F
COMPRESSOR SHUTDOWN - Evaporator Pressure Low #3
119
F
COMPRESSOR SHUTDOWN - Evaporator Pressure Sensor Fault
COMPRESSOR SHUTDOWN - Evaporator Pressure Sensor Fault
120
F
#1
COMPRESSOR SHUTDOWN - Evaporator Pressure Sensor Fault
121
F
#2
COMPRESSOR SHUTDOWN - Evaporator Pressure Sensor Fault
122
F
#3
124
F
COMPRESSOR SHUTDOWN - Ground Fault Trip #1
125
F
COMPRESSOR SHUTDOWN - Ground Fault Trip #2
126
F
COMPRESSOR SHUTDOWN - Ground Fault Trip #3
128
F
COMPRESSOR SHUTDOWN - Lift Pressure Low #1
129
F
COMPRESSOR SHUTDOWN - Lift Pressure Low #2
130
F
COMPRESSOR SHUTDOWN - Lift Pressure Low #3
COMPRESSOR SHUTDOWN - Liquid Line Pressure Sensor Fault
132
F
#1
COMPRESSOR SHUTDOWN - Liquid Line Pressure Sensor Fault
133
F
#2
COMPRESSOR SHUTDOWN - Liquid Line Pressure Sensor Fault
134
F
#3
COMPRESSOR SHUTDOWN - Liquid Line Temperature Sensor
136
F
Fault #1
1-AGS 'C' Vintage Only (two circuits only)
2-AGS 'B' Vintage Only (up to three circuits)
3-ACZ Dual Circuit Only
4-ACZ Single Circuit Only
5-AGZ Dual Circuit Only
6-AGZ Single Circuit Only
7-Solid State Starter Option required. Not available on WMC.
8-WMC Only.
www.DaikinApplied.com
WSC, WDC,
WPV, HSC,
Event Values
HDC, TSC,
WMC, WCC
1,2,9,10
1,2,3,4,9,10
X
7
1,2,3,4,9,10
X
7
1,2,9,10
1,2,3,4,9,10
X
1,2,3,4,9,10
1,2,3,4,9,10
X
1,2,9,10
1,2,3,4,9
X
1,2,3,4,9,10
X
1,2,3,4,9,10
X
1,2,3,4,9,10
X
1,2,9,10
1,2,3,4,9
X
1,2,3,4,9
X
X
1,2,3,4,9,10
1,2,3,4,9,10
X
1,2,9,10
1,2,3,4,9,10
X
1,2,3,4,9,10
X
1,2,9,10
1,2,3,4,9,10
1,2,3,4,9,10
X
1,2,3,4,9,10
1,2,3,4,9,10
1,2,3,4,9,10
X
1,2,3,4,9,10
X
1,2,9,10
1,2,3,4,9,10
1,2,3,4,9,10
X
1,2,3,4,9,10
X
1,2,9,10
1,2,3,4,9,10
X
7
1,2,3,4,9,10
X
7
1,2,9,10
1,2,9,10
1,2,9,10
1,2,9,10
1,2,9,10
1,2,9,10
1,2,9,10
1,2,9,10
93
ED 15062-7 • MICROTECH II CHILLER CONTROLLER
C
a
-baC
learIng
larms
AGZ
ACZ
WGZ, TGZ
AGS
X
2
X
X
X
2
X
6
X
4
X
X
X
X
5
3
X
X
X
X
5
3
X
2
X
X
X
6
4
X
X
X
X
5
3
X
X
X
X
5
3
X
2
X
X
X
2
X
X
X
2
X
X
X
X
X
X
X
X
X
6
X
4
X
5
X
3
X
X
X
5
X
3
X
X
X
2
X
X
6
4
X
X
X
X
5
3
X
5
X
3
X
X
X
2
X
X
X
6
1
X
6
X
X
1
X
2
X
X
X
2
X
X
X
2
X
neT
WGS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MicroTech II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents