Data descriptions
10.5 Process data
10.5.2.3

S_ZSW1: Safety status word 1

S_ZSW1 (Basic Functions)
Safety status word 1 (S_ZSW1)
S_ZSW1, input signals
see function diagram [2806].
Table 10-12 Description of safety status word 1 (S_ZSW1)
Byte
Bit
0
0
1
2
3
4
5
6
7
1
0
1
2
3
4
5
6
7
Signals not relevant for Basic Functions: Must not be evaluated.
1)
362
Meaning
STO active
SS1 active
SS2 active
SOS active
SLS active
Reserved
SLP active
Internal Event
SLA active
Active SLS level bit 0
Active SLS level bit 1
SOS selected
SDI positive active
SDI negative active
Reserved
SSM (speed below limit value)
1
STO active
0
STO not active
1
SS1 active
0
SS1 not active
0
1)
0
1)
0
1)
0
1)
1
Internal event
0
No internal event
0
1)
0
1)
0
0
1)
0
1)
0
1)
0
1)
Safety Integrated (with SINAMICS S120)