JOG NOW Excite +: Service & maintenance manual - rev. 5.1
4.3. MONITOR PLUG FOR C-SAFE PORT
When the plug code 0WC00639AA is fitted into any one of the C-Safe ports on the machine, the
corresponding LED should illuminate to indicate the presence of the 5Vdc supply on the port.
During the C-Safe port test function, the plug connects the transmit channel directly to the receive
channel, thereby producing a positive test outcome if the port is functioning correctly.
4.4. VISIOWEB UPGRADE
4.4.1. VISIO
VISIOWEB
VS
The 2 product versions differ mainly for 2 reasons, one it's about its functionality while the second
it's about a technical characteristic... They are briefly detailed below:
1. On machines with VISIOWEB display it is possible for the user browsing and use internet
services during the training session;
2. VISIOWEB has been developed on Linux instead of Windows CE used for VISIO. This
difference can not be noticed by the final user because on both the product versions there is
the same user interface and just few steps of the net configuration are different.
4.4.2. VISIOWEB
It is possible to upgrade equipment from VISIO to VISIOWEB through a specific SW upgrade
procedure, using the proper USB recovery stick and a correct configuration for internet service (if
the infrastructure has been properly arranged).
The code to be used for this upgrade ATS600
CAUTION: this procedure must mandatory be done by a TECHNOGYM qualified
engineer.
VISIO
UPGRADE FOR
MODELS
Page 4.3